AEMC 2138.07 Multi-Function Installation Tester Model C.A 6117 (US)
SKU 2138.07
Model Number: AEM213807
Availability Notice:
Availability to purchase does not guarantee immediate stock. Our site displays items we stock along with items we have the access to source for our customers. Some items may have extended lead times. Questions about availability? Contact our team before ordering.
SPECIAL ORDER ONLY - Extended Lead Times
Includes DataView® Software
The High performance C.A6117 offers excellent measurement stability, even in electrically noisy industrial environments. All the measurements needed to test an electrical installation are available: continuity, resistance, insulation, ground resistance, selective earth measurements, loop impedance and type A and AC RCDs (GFCI circuits). The 6117 can also be used to measure voltage, frequency, AC current (via a current clamp), active power, harmonics and phase rotation.
The C.A6117 is also equipped with type B RCD testing, a built in fuse table and a voltage drop feature.
| CONTINUITY / RESISTANCE | |
| I Rated / Range / Resolution | I > 200mA / 39.99Ω/ 0.01Ω / ± (1.5% of R + 2cts) 12mA / 39.99Ω & 399.9Ω / 0.01 & 0.1Ω /± (1.5% of R + 5cts) with beep |
| Range / Resolution / Accuracy | 4 kΩ/ 1Ω / ±(1.5% of R + 5cts) 40 kΩ - 400kΩ/ 10Ω - 100Ω / ±(1.5% of R + 2cts) |
| INSULATION | |
| Rated Voltage | Utest: 50 /100 / 250 / 500 / 1000VDC |
| Range / Resolution / Accuracy | 0.01MΩ to 2GΩ / 10kΩ to 1MΩ / ±(5% of R + 3cts) |
| Short Circuit Current | ≤ 3mA |
| GROUND | |
| 3P GROUND Range / Resolution / Accuracy |
0.50 to 40Ω/ 0.01Ω / ±(2% of R + 10cts) 40Ω to 15kΩ / 0.1 to 1Ω / ±(2% of R + 2cts) 15 to 40kΩ / 10Ω/ ±(10% of R + 2cts) |
| Others | Measurement of resistance of auxiliary stakes RH & RS (up to 40kΩ) |
| Ufk | Complies with SEV 3569 |
| 1P SELECTIVE GROUND Range / Resolution / Accuracy |
0.20 to 39.99Ω - 40 to 399.9Ω / 0.01 to 0.1Ω / ±(10% of R + 10cts) (ISel via clamp) |
| LOOP IMPEDANCE (Zs (L-PE0 AND Zi (L-N OR L-L) – 1P LIVE GROUND | |
| Live Ground Installation Voltage / Frequency |
90 to 500 V / 15.8 to 17.5Hz - 45 to 65Hz |
| High-current mode with TRIP Zs (L- PE) & Zi (L- N or L - L) Range / Resolution / Accuracy |
Max. test current: 7.5 A (0.050) 0.100 to 0.5Ω / 0.001Ω/ ±(10% of R + 20cts) • 0.5Ω to 3.999Ω / 0.001Ω/ ±(5% of R + 20cts) 3.999 to 39.99Ω/ 0.01Ω / ±(5% of R + 2cts) • 39.99 to 399.99Ω / 0.1Ω/ ±(5% of R + 2cts) |
| NO TRIP mode (Zs (L – PE) 0nly) | Test current 6mA – 9mA – 12mA (as required) 0.20 to 0.99Ω / 0.01Ω / ±(15% of R + 10cts) 1.00 to 1.99Ω / 0.01Ω / ± (15% of R + 3cts) 2.00 to 39.99 / 0.01Ω / ± (10% of R + 3cts) 40.00 to 399.9Ω / 0.1Ω ± (5% of R + 2cts) 400 to 3999Ω / 1Ω ±(5% of R + 2cts) |
| Calculation of IK short circuit current (PFC (Zs), I Sc PSCC (Zi) | Fault current and short-circuit current: 0.1 to20kA |
| Integrated Fuse Table | Yes |
| Voltage drop |
-40% to +40% |
| Others | Measurement of the resistive and inductive components of Zs and Zi impedances |
| AC and type RCDs | |
| Installation voltage / Frequency | 90 to 500V / 15.8 to 17.5Hz and 45 to 65Hz |
| IΔn | 10/30/100/500/650/1,000 (90V - 280V) or variable ramp and pulse test |
| N-trip test | At ½ IΔn – Duration 1000ms or 2000ms |
| Ramp mode | 0.2 to 0.5 x IΔn(Uf) / 0.3 x IΔn to 1.06 IΔn increments of 3.3% x IΔn |
| Trip test: R: Range / Resolution / Accuracy |
0.2 to 0.5 x IΔn(Uf) / 0.5 x IΔn / 2 x IΔn(selective) / 5 x IΔn Pulse: 0 to 500ms/0.1 and 1ms / 2ms, Ramp mode: 0 to 200 ms / 0.1 ms / 2 ms |
| B-Type RCDs | |
| Installation Voltage / Frequency | 90 to 275V / 15.8 to 17.5Hz and 45 to 65Hz |
| IΔn: ramp / pulse 2 x IΔn pulse 4 x IΔn |
10/30/100/500mA 10/30/100/500 mA with pulse 4 IΔn Duration: 150 ms with 4 x IΔn or 300 ms with 2 x IΔn |
| Test in ramp mode | 0.2 x IΔn to 2.2 x IΔn |
| Trip test: 2 x IΔn 4 x IΔn |
IΔn ≤ 200 mA: 2.2 x 2 x IΔn IΔn ≤ 200 mA: 1.1 x 2 x IΔn IΔn ≤ 100 mA: 2.2 x 4 x IΔn |
| OTHER MEASUREMENTS | |
| Current by Current Probe C177A | 5.0mA t0 199.9A |
| Current by Current Probe MN77 | (1mA*) 5.0mA to 19.99A |
| Voltage | 0 to 550VAC/DC / DC and 158 to 500Hz |
| Frequency | 10 to 500Hz |
| Phase rotation | 20 to 500VAC |
| Active power | 0 to 110kW single phase – 0 to 330kW three-phase Simultaneous display of voltage and current waveforms |
| Harmonics | Voltage and Current / up to 50th order / THD-F / THD-R |
| GENERAL SPECIFICATIONS | |
| Display | Large 5.7” backlit graphic color LCD 320 x 240 pixels |
| Storage/Communication | USB for data transfer to Dataview software (Included) |
| Power Supply | Rechargeable battery Lithium-Ion 10.8V, 5.8Ah |
| Battery Life | Up to 30 hours |
| Protection | IP 53 / IK04 |
| Dimension / Weight | 11 x 7.48 x 5.04” (280 x190 x 128mm) 4.85 lbs (2.2 kg) |
| EMC | IEC61326-1 |
| Safety | IEC61010-1 – 600V CAT III – 300V CAT IV – IEC 61557 |