AEMC 2136.43 PowerPad® III Model 8436 (No Sensors - Waterproof IP67)
Número de modelo: AEM213643
The PowerPad® III Model 8436 is a three-phase power quality analyzer that is easy-to-use, compact and shock resistant. It enables technicians and engineers to measure and carry out diagnostics and power quality work on one-, two- or three- phase networks. Five voltage and four current inputs are provided. It is IEC 61000-4-30 Class B and safety rated to 600 V CAT IV. It is rated IP67 when used with the flexible sensor Ampflex® 196 A.
The Model 8436 can record 2 GB of trend data on a memory card. Additional internal memory is used to let you store alarms, transients, and snapshot data. The user can store up to 50 screen snapshots, up to 210 captured transients that contain four cycles for each active input, and >16,000 alarm events from up to 40 different parameters. Trend data can also be recorded for days, weeks, or even months. Inrush current can also be captured and stored.
IMPORTANT WARRANTY NOTE: By registering online within 30 days from the date of purchase, your warranty will be extended to 3 years.
| Inputs | 4 Voltage / 4 Current | ||||
| Sample Rate | 256 per Cycle | 12.8 kHz at 50 Hz | 15.36 kHz at 60 Hz | ||
| Specification | Range | Measurement Range | Resolution | Accuracy (Typical) | |
| Volt | |||||
| Vrms (AC + DC) | 1000 V P to N 2000 V P to P |
(2 to 1000) V | 0.1 V | ±0.5 % Rdg + 200 mV | |
| Vpk | 1414 V | (2 to 1000) V | 0.1 V | ± 3 % Rdg + 2 V | |
| Vrms Half Cycle | 1000 V P to N 2000 V P to P |
(2 to 1000) V | 0.1 V | ± 0.8 % Rdg + 1 V | |
| Amps (accuracy excluding clamp accuracy) | |||||
| Amps (AC + DC) | SR193 & MR193 MN193 5 A MN193 100 A |
(1 to 1000) A 5 mA to 5 A 100 mA to 100 A |
0.1 A 1 mA 10 mA |
± 0.5 % Rdg + 200 mA ± 0.5 % Rdg + 2mA ± 0.5% Rdg + 20 mA |
|
| AmpFlex& MiniFlex | Range 100 A Range 6500 A Range 10 kA |
100 mA to 100 A (10 to 6500) A 10 A to 10 kA |
10 mA (0.1 and 1) A 1 A |
± 0.5 % Rdg + 3 0mA ± 0.5 % Rdg + 3 A ± 0.5 % Rdg + 3 A |
|
| Apk | SR193 & MR193 MN193 5A MN193 100A |
(1 to 1414) A 5 mA to 7.017 A 100 mA to 141.4 A |
0.1 A 1 mA 10 mA |
±1 % Rdg + 2 A ±1 % Rdg + 20 mA ±1 % Rdg + 200 mA |
|
|
Apk AmpFlex & MiniFlex |
Range 100 A Range 6500 A Range 10 kA |
100 mA to 100 A (10 to 6500) A 10 A to 10 kA |
1 A (0.1 and 1) A 1 A |
± 3% Rdg + 600 mA ± 3 % Rdg + 5 A ± 3 % Rdg + 5 A |
|
| A Half Cycle | SR193 & MR193 MN193 5 A MN193 100 A |
(1 to 1200) A 5 mA to 6 A 100 mA to 120 A |
0.1 A 1 mA 10 mA |
± 1 % Rdg + 1 A ± 1 % Rdg + 10 mA ± 1 % Rdg + 100 mA |
|
| Frequency | 40 to 70 Hz | 0.01 | ±0.01 Hz | ||
| Power | |||||
| Watts (VA, var) P-Q-S |
Probes: AmpFlex, MiniFlex |
(10 to 10) MW (10 to 10) MW |
4 digits min 4 digits min |
± 1 % Rdg ± 1.5 % Rdg |
|
| Power Factor (Cos Φ/DPF) | -1.000 to 1.000 | 0.001 | ± 1 ° for Φ, + 5 cts for cos Φ |
||
| Energy | |||||
| kWh (kVAh, kvarh) P-Q-S | (1 to 9,999,999) MWh (MVAh, Mvarh) | ± 1 % Rdg | |||
| Harmonics | DC, 1 to 50 | ||||
| Volts & Amp % | f r Absolute V Absolute A THD |
(0.0 to 1500) % (0.0 to 100) % (0.0 to 1000) V (0.0 to 1000) A (0.0 to 999.9) % |
0.1 % 0.1 % 0.1 V 0.1 A 0.1 % |
± 2.5 % Rdg + 5 cts ± 2.5 % Rdg + 5 cts ± 2.5 % Rdg + 1 V ± 2% Rdg + 1 A ± 2.5 % Rdg + 5 cts |
|
| Phase Angle | (-179 to 180) ° | 1 ° | ± 1.5 ° + 1 °x (n/12.5) | ||
| Also display Energy loss, Flicker, Plt (2H), Pst (10min), Unbalance V% & A% | |||||
| General Features | |||||
| Programmable Alarm | Up to 40 types: up to 16,362 recorded max | ||||
| Transient Capture | Up to 210 | ||||
| Snapshot | Up to 50 (screen BMP + all channels data) | ||||
| Interface | Isolated USB, SD card, and Dataview software for real time data, configuration, and reporting included | ||||
| Memory | SD card (SDHC compliant, not formatted) standard, for trend Data, Internal memory for In-Rush, transients and alarms | ||||
| Display | Color TFT 320 x 240 (1/4 OFT) with graphic representation of system parameters and measurements | ||||
| Real-Time Clock | Time and date stamp for Trend mode, Transient display, System Monitor and event capture | ||||
| Power Supply | External from (110 to 1000) V DC to 440 Hz | ||||
| Charging Time | 6 h approx. | ||||
| Battery Backup | Rechargeable 9.6 V NiMH 4000 mA battery pack | ||||
| Battery Life | ≥10 h when display ON | ||||
| Dimensions (L x W x H) | (10.6 x 9.85 x 7.09) in (270 x 250 x 180) mm | ||||
| Weight | 8.16 lbs (3.7 kg) | ||||
| Altitude Operating | 2000 m (6560 ft) | ||||
| Operating Temperature | (32 to 122) °F (0 to 50) °C | ||||
| Storage Temperature | (-4 to 122) °F (-20 to 50) °C | ||||
| IP Rating | IP67 per IEC 60529 when housing close and A196 sensor used | ||||
| Safety |
IEC/EN 61010-1 (1000 V CAT III-600 V CAT IV), IEC 1326-1
|
||||